Eaton SMDJE130A TVS Diode, 209 V Clamp
Eaton SMDJE130A TVS Diode, 209 V Clamp

Eaton SMDJE130A TVS Diode, 209 V Clamp

Share
SMDJE130A: transient voltage suppressor diode, 130 V standoff, 209 V clamp, 14.4 A pulse, 3000 W, unidirectional.
    • Product Details
    • Download

    Eaton SMDJE130A TVS Diode, 209 V Clamp

    SMDJE130A at a glance: transient voltage suppressor diode, 130 V standoff, 209 V clamp, 14.4 A pulse, 3000 W, unidirectional.

    Key Specifications

    ParameterValue
    Orderable part numberSMDJE130A
    Standoff voltage (VR)130 V
    Leakage current at VR1 uA
    Breakdown voltage at IT144 V to 159 V
    Test current (IT)1 mA
    Clamping voltage at IPP209 V
    Peak pulse current14.4 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us3000 W
    PackageSMC (DO-214AB)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11217

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11217; the package line above is the
    body the part is built in.

    Reading the Data Sheet

    The peak pulse power rating is a 10/1000 microsecond figure: a 400 W part takes 400 W for one millisecond, not continuously. Shorter pulses allow more current, longer ones less, which is what the derating curves in the data sheet show.

    The breakdown window spans 10.42 percent, from 144 V to 159 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 130 V standing the leakage is at most 1 uA, so the part draws 0.13 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMDJ family this is item 107 of 123 in the Eaton catalogue.

    What This Family Is For

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.