Eaton SMDJE200A TVS Diode, 324 V Clamp
Eaton SMDJE200A TVS Diode, 324 V Clamp

Eaton SMDJE200A TVS Diode, 324 V Clamp

Share
SMDJE200A: transient voltage suppressor diode, 200 V standoff, 324 V clamp, 9.3 A pulse, 3000 W, unidirectional.
    • Product Details
    • Download

    Eaton SMDJE200A TVS Diode, 324 V Clamp

    SMDJE200A at a glance: transient voltage suppressor diode, 200 V standoff, 324 V clamp, 9.3 A pulse, 3000 W, unidirectional.

    Specification Table

    ParameterValue
    Orderable part numberSMDJE200A
    Standoff voltage (VR)200 V
    Leakage current at VR1 uA
    Breakdown voltage at IT224 V to 247 V
    Test current (IT)1 mA
    Clamping voltage at IPP324 V
    Peak pulse current9.3 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us3000 W
    PackageSMC (DO-214AB)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11217

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11217; the package line above is the
    body the part is built in.

    The Figures Explained

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 10.27 percent, from 224 V to 247 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 200 V standing the leakage is at most 1 uA, so the part draws 0.2 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMDJ family this is item 119 of 123 in the Eaton catalogue.

    What This Family Is For

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • The pulse current is quoted for one waveform. A different waveform changes the allowable current, and the derating curve, not the single number, is the guide.
    • Bidirectional parts are two junctions back to back in one package. They clamp symmetrically, at the cost of roughly double the capacitance of a unidirectional part of the same die.

    Frequently Asked Questions

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.