Eaton SMF100CAH 100 V 200 W TVS Diode
Eaton SMF100CAH 100 V 200 W TVS Diode

Eaton SMF100CAH 100 V 200 W TVS Diode

Share
SMF100CAH: transient voltage suppressor diode, 100 V standoff, 162 V clamp, 1.2 A pulse, 200 W, bidirectional.
    • Product Details
    • Download

    Eaton SMF100CAH 100 V 200 W TVS Diode

    SMF100CAH at a glance: transient voltage suppressor diode, 100 V standoff, 162 V clamp, 1.2 A pulse, 200 W, bidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part numberSMF100CAH
    Standoff voltage (VR)100 V
    Leakage current at VR1 uA
    Breakdown voltage at IT111 V to 123 V
    Test current (IT)1 mA
    Clamping voltage at IPP162 V
    Peak pulse current1.2 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us200 W
    PackageSOD-123FL
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1066

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1066; the package line above is the
    body the part is built in.

    The Figures Explained

    These parts are avalanching junctions, so they clamp harder than a varistor and recover without the voltage drift a metal oxide part shows after a surge. The trade is capacitance and a sharper failure mode.

    The breakdown window spans 10.81 percent, from 111 V to 123 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 100 V standing the leakage is at most 1 uA, so the part draws 0.1 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMF family this is item 158 of 177 in the Eaton catalogue.

    What This Family Is For

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • The pulse current is quoted for one waveform. A different waveform changes the allowable current, and the derating curve, not the single number, is the guide.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Shenzhen Gaorunxin Technology Co., Ltd