Eaton SMF10AH TVS Diode, 17 V Clamp
Eaton SMF10AH TVS Diode, 17 V Clamp

Eaton SMF10AH TVS Diode, 17 V Clamp

Share
SMF10AH: transient voltage suppressor diode, 10 V standoff, 17 V clamp, 11.8 A pulse, 200 W, unidirectional.
    • Product Details
    • Download

    Eaton SMF10AH TVS Diode, 17 V Clamp

    SMF10AH at a glance: transient voltage suppressor diode, 10 V standoff, 17 V clamp, 11.8 A pulse, 200 W, unidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part numberSMF10AH
    Standoff voltage (VR)10 V
    Leakage current at VR1 uA
    Breakdown voltage at IT11.1 V to 12.3 V
    Test current (IT)1 mA
    Clamping voltage at IPP17 V
    Peak pulse current11.8 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us200 W
    PackageSOD-123FL
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1066

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1066; the package line above is the
    body the part is built in.

    How to Read These Ratings

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 10.81 percent, from 11.1 V to 12.3 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 10 V standing the leakage is at most 1 uA, so the part draws 0.01 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMF family this is item 18 of 130 in the Eaton catalogue.

    Where This Series Fits

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.