Eaton SMF10ALH Transient Voltage Suppressor 10 V
Eaton SMF10ALH Transient Voltage Suppressor 10 V

Eaton SMF10ALH Transient Voltage Suppressor 10 V

Share
SMF10ALH: transient voltage suppressor diode, 10 V standoff, 17 V clamp, 23.5 A pulse, 400 W, bidirectional.
    • Product Details
    • Download

    Eaton SMF10ALH Transient Voltage Suppressor 10 V

    SMF10ALH at a glance: transient voltage suppressor diode, 10 V standoff, 17 V clamp, 23.5 A pulse, 400 W, bidirectional.

    Key Specifications

    ParameterValue
    Orderable part numberSMF10ALH
    Standoff voltage (VR)10 V
    Leakage current at VR2 uA
    Breakdown voltage at IT11.1 V to 12.3 V
    Test current (IT)1 mA
    Clamping voltage at IPP17 V
    Peak pulse current23.5 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us400 W
    PackageSOD-123FL
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1067

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1067; the package line above is the
    body the part is built in.

    Reading the Data Sheet

    These parts are avalanching junctions, so they clamp harder than a varistor and recover without the voltage drift a metal oxide part shows after a surge. The trade is capacitance and a sharper failure mode.

    The breakdown window spans 10.81 percent, from 11.1 V to 12.3 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 10 V standing the leakage is at most 2 uA, so the part draws 0.02 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMF family this is item 17 of 177 in the Eaton catalogue.

    What This Family Is For

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • The pulse current is quoted for one waveform. A different waveform changes the allowable current, and the derating curve, not the single number, is the guide.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products