Eaton SMF10CALH 10 V 400 W TVS Diode
Eaton SMF10CALH 10 V 400 W TVS Diode

Eaton SMF10CALH 10 V 400 W TVS Diode

Share
SMF10CALH: transient voltage suppressor diode, 10 V standoff, 17 V clamp, 23.5 A pulse, 400 W, bidirectional.
    • Product Details
    • Download

    Eaton SMF10CALH 10 V 400 W TVS Diode

    SMF10CALH at a glance: transient voltage suppressor diode, 10 V standoff, 17 V clamp, 23.5 A pulse, 400 W, bidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part numberSMF10CALH
    Standoff voltage (VR)10 V
    Leakage current at VR2 uA
    Breakdown voltage at IT11.1 V to 12.3 V
    Test current (IT)1 mA
    Clamping voltage at IPP17 V
    Peak pulse current23.5 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us400 W
    PackageSOD-123FL
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1067

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1067; the package line above is the
    body the part is built in.

    Reading the Data Sheet

    The peak pulse power rating is a 10/1000 microsecond figure: a 400 W part takes 400 W for one millisecond, not continuously. Shorter pulses allow more current, longer ones less, which is what the derating curves in the data sheet show.

    The breakdown window spans 10.81 percent, from 11.1 V to 12.3 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 10 V standing the leakage is at most 2 uA, so the part draws 0.02 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMF family this is item 20 of 177 in the Eaton catalogue.

    Series Positioning

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message