Eaton SMF110AH TVS Diode, 177 V Clamp
Eaton SMF110AH TVS Diode, 177 V Clamp

Eaton SMF110AH TVS Diode, 177 V Clamp

Share
SMF110AH: transient voltage suppressor diode, 110 V standoff, 177 V clamp, 1.1 A pulse, 200 W, unidirectional.
    • Product Details
    • Download

    Eaton SMF110AH TVS Diode, 177 V Clamp

    SMF110AH at a glance: transient voltage suppressor diode, 110 V standoff, 177 V clamp, 1.1 A pulse, 200 W, unidirectional.

    Ratings at a Glance

    ParameterValue
    Orderable part numberSMF110AH
    Standoff voltage (VR)110 V
    Leakage current at VR1 uA
    Breakdown voltage at IT122 V to 135 V
    Test current (IT)1 mA
    Clamping voltage at IPP177 V
    Peak pulse current1.1 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us200 W
    PackageSOD-123FL
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1066

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1066; the package line above is the
    body the part is built in.

    What the Numbers Mean

    The peak pulse power rating is a 10/1000 microsecond figure: a 400 W part takes 400 W for one millisecond, not continuously. Shorter pulses allow more current, longer ones less, which is what the derating curves in the data sheet show.

    The breakdown window spans 10.66 percent, from 122 V to 135 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 110 V standing the leakage is at most 1 uA, so the part draws 0.11 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMF family this is item 113 of 130 in the Eaton catalogue.

    Where This Series Fits

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.