SMF12CAH: transient voltage suppressor diode, 12 V standoff, 19.9 V clamp, 10.1 A pulse, 200 W, bidirectional.
    • Product Details
    • Download

    Eaton SMF12CAH 12 V 200 W TVS Diode

    SMF12CAH at a glance: transient voltage suppressor diode, 12 V standoff, 19.9 V clamp, 10.1 A pulse, 200 W, bidirectional.

    Specification Table

    ParameterValue
    Orderable part numberSMF12CAH
    Standoff voltage (VR)12 V
    Leakage current at VR1 uA
    Breakdown voltage at IT13.3 V to 14.7 V
    Test current (IT)1 mA
    Clamping voltage at IPP19.9 V
    Peak pulse current10.1 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us200 W
    PackageSOD-123FL
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1066

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1066; the package line above is the
    body the part is built in.

    The Figures Explained

    These parts are avalanching junctions, so they clamp harder than a varistor and recover without the voltage drift a metal oxide part shows after a surge. The trade is capacitance and a sharper failure mode.

    The breakdown window spans 10.53 percent, from 13.3 V to 14.7 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 12 V standing the leakage is at most 1 uA, so the part draws 0.012 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMF family this is item 29 of 177 in the Eaton catalogue.

    Series Positioning

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • Bidirectional parts are two junctions back to back in one package. They clamp symmetrically, at the cost of roughly double the capacitance of a unidirectional part of the same die.

    Frequently Asked Questions

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.