Eaton SMF15CALH 15 V 400 W TVS Diode
Eaton SMF15CALH 15 V 400 W TVS Diode

Eaton SMF15CALH 15 V 400 W TVS Diode

Share
SMF15CALH: transient voltage suppressor diode, 15 V standoff, 24.4 V clamp, 16.4 A pulse, 400 W, bidirectional.
    • Product Details
    • Download

    Eaton SMF15CALH 15 V 400 W TVS Diode

    SMF15CALH at a glance: transient voltage suppressor diode, 15 V standoff, 24.4 V clamp, 16.4 A pulse, 400 W, bidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part numberSMF15CALH
    Standoff voltage (VR)15 V
    Leakage current at VR1 uA
    Breakdown voltage at IT16.7 V to 18.5 V
    Test current (IT)1 mA
    Clamping voltage at IPP24.4 V
    Peak pulse current16.4 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us400 W
    PackageSOD-123FL
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1067

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1067; the package line above is the
    body the part is built in.

    How to Read These Ratings

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 10.78 percent, from 16.7 V to 18.5 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 15 V standing the leakage is at most 1 uA, so the part draws 0.015 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMF family this is item 45 of 177 in the Eaton catalogue.

    Series Positioning

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products