Eaton SMF200CAH 200 V 200 W TVS Diode
Eaton SMF200CAH 200 V 200 W TVS Diode

Eaton SMF200CAH 200 V 200 W TVS Diode

Share
SMF200CAH: transient voltage suppressor diode, 200 V standoff, 324 V clamp, 0.6 A pulse, 200 W, bidirectional.
    • Product Details
    • Download

    Eaton SMF200CAH 200 V 200 W TVS Diode

    SMF200CAH at a glance: transient voltage suppressor diode, 200 V standoff, 324 V clamp, 0.6 A pulse, 200 W, bidirectional.

    Ratings at a Glance

    ParameterValue
    Orderable part numberSMF200CAH
    Standoff voltage (VR)200 V
    Leakage current at VR1 uA
    Breakdown voltage at IT224 V to 247 V
    Test current (IT)1 mA
    Clamping voltage at IPP324 V
    Peak pulse current0.6 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us200 W
    PackageSOD-123FL
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1066

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1066; the package line above is the
    body the part is built in.

    The Figures Explained

    A transient voltage suppressor is a diode biased so that it stays off at the working voltage and breaks down in a surge. The three numbers that decide whether it fits are the standoff voltage, the breakdown window and the clamping voltage at the pulse current you expect.

    The breakdown window spans 10.27 percent, from 224 V to 247 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 200 V standing the leakage is at most 1 uA, so the part draws 0.2 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMF family this is item 174 of 177 in the Eaton catalogue.

    What This Family Is For

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.