Eaton SMF26ALH 26 V 400 W TVS Diode
Eaton SMF26ALH 26 V 400 W TVS Diode

Eaton SMF26ALH 26 V 400 W TVS Diode

Share
SMF26ALH: transient voltage suppressor diode, 26 V standoff, 42.1 V clamp, 9.5 A pulse, 400 W, bidirectional.
    • Product Details
    • Download

    Eaton SMF26ALH 26 V 400 W TVS Diode

    SMF26ALH at a glance: transient voltage suppressor diode, 26 V standoff, 42.1 V clamp, 9.5 A pulse, 400 W, bidirectional.

    Ratings at a Glance

    ParameterValue
    Orderable part numberSMF26ALH
    Standoff voltage (VR)26 V
    Leakage current at VR1 uA
    Breakdown voltage at IT28.9 V to 31.9 V
    Test current (IT)1 mA
    Clamping voltage at IPP42.1 V
    Peak pulse current9.5 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us400 W
    PackageSOD-123FL
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1067

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1067; the package line above is the
    body the part is built in.

    What the Numbers Mean

    The peak pulse power rating is a 10/1000 microsecond figure: a 400 W part takes 400 W for one millisecond, not continuously. Shorter pulses allow more current, longer ones less, which is what the derating curves in the data sheet show.

    The breakdown window spans 10.38 percent, from 28.9 V to 31.9 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 26 V standing the leakage is at most 1 uA, so the part draws 0.026 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMF family this is item 74 of 177 in the Eaton catalogue.

    Positioning in the Range

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • The pulse current is quoted for one waveform. A different waveform changes the allowable current, and the derating curve, not the single number, is the guide.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products