Eaton SMF33AH Transient Voltage Suppressor 33 V
Eaton SMF33AH Transient Voltage Suppressor 33 V

Eaton SMF33AH Transient Voltage Suppressor 33 V

Share
SMF33AH: transient voltage suppressor diode, 33 V standoff, 53.3 V clamp, 3.8 A pulse, 200 W, unidirectional.
    • Product Details
    • Download

    Eaton SMF33AH Transient Voltage Suppressor 33 V

    SMF33AH at a glance: transient voltage suppressor diode, 33 V standoff, 53.3 V clamp, 3.8 A pulse, 200 W, unidirectional.

    Ratings at a Glance

    ParameterValue
    Orderable part numberSMF33AH
    Standoff voltage (VR)33 V
    Leakage current at VR1 uA
    Breakdown voltage at IT36.7 V to 40.6 V
    Test current (IT)1 mA
    Clamping voltage at IPP53.3 V
    Peak pulse current3.8 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us200 W
    PackageSOD-123FL
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1066

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1066; the package line above is the
    body the part is built in.

    The Figures Explained

    The standoff voltage has to sit above the highest steady state level on the line, including regulation and ripple. The breakdown voltage is then one diode drop above that, and the clamp is what the downstream circuit actually sees.

    The breakdown window spans 10.63 percent, from 36.7 V to 40.6 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 33 V standing the leakage is at most 1 uA, so the part draws 0.033 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMF family this is item 63 of 130 in the Eaton catalogue.

    Where This Series Fits

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.