Eaton SMF36CALH TVS Diode, 58.1 V Clamp
Eaton SMF36CALH TVS Diode, 58.1 V Clamp

Eaton SMF36CALH TVS Diode, 58.1 V Clamp

Share
SMF36CALH: transient voltage suppressor diode, 36 V standoff, 58.1 V clamp, 6.9 A pulse, 400 W, bidirectional.
    • Product Details
    • Download

    Eaton SMF36CALH TVS Diode, 58.1 V Clamp

    SMF36CALH at a glance: transient voltage suppressor diode, 36 V standoff, 58.1 V clamp, 6.9 A pulse, 400 W, bidirectional.

    Ratings at a Glance

    ParameterValue
    Orderable part numberSMF36CALH
    Standoff voltage (VR)36 V
    Leakage current at VR1 uA
    Breakdown voltage at IT40 V to 44.2 V
    Test current (IT)1 mA
    Clamping voltage at IPP58.1 V
    Peak pulse current6.9 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us400 W
    PackageSOD-123FL
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1067

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1067; the package line above is the
    body the part is built in.

    What the Numbers Mean

    The standoff voltage has to sit above the highest steady state level on the line, including regulation and ripple. The breakdown voltage is then one diode drop above that, and the clamp is what the downstream circuit actually sees.

    The breakdown window spans 10.5 percent, from 40 V to 44.2 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 36 V standing the leakage is at most 1 uA, so the part draws 0.036 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMF family this is item 97 of 177 in the Eaton catalogue.

    Series Positioning

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • Bidirectional parts are two junctions back to back in one package. They clamp symmetrically, at the cost of roughly double the capacitance of a unidirectional part of the same die.

    Frequently Asked Questions

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.