Eaton SMF51CA Transient Voltage Suppressor 51 V
Eaton SMF51CA Transient Voltage Suppressor 51 V

Eaton SMF51CA Transient Voltage Suppressor 51 V

Share
SMF51CA: transient voltage suppressor diode, 51 V standoff, 82.4 V clamp, 2.4 A pulse, 200 W, bidirectional.
    • Product Details
    • Download

    Eaton SMF51CA Transient Voltage Suppressor 51 V

    SMF51CA at a glance: transient voltage suppressor diode, 51 V standoff, 82.4 V clamp, 2.4 A pulse, 200 W, bidirectional.

    Key Specifications

    ParameterValue
    Orderable part numberSMF51CA
    Standoff voltage (VR)51 V
    Leakage current at VR1 uA
    Breakdown voltage at IT56.7 V to 62.7 V
    Test current (IT)1 mA
    Clamping voltage at IPP82.4 V
    Peak pulse current2.4 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us200 W
    PackageSOD-123FL
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1560

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1560; the package line above is the
    body the part is built in.

    The Figures Explained

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 10.58 percent, from 56.7 V to 62.7 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 51 V standing the leakage is at most 1 uA, so the part draws 0.051 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMF family this is item 120 of 177 in the Eaton catalogue.

    Positioning in the Range

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products