SMF58AH: transient voltage suppressor diode, 58 V standoff, 93.6 V clamp, 2.1 A pulse, 200 W, unidirectional.
    • Product Details
    • Download

    Eaton SMF58AH Transient Voltage Suppressor 58 V

    SMF58AH at a glance: transient voltage suppressor diode, 58 V standoff, 93.6 V clamp, 2.1 A pulse, 200 W, unidirectional.

    Ratings at a Glance

    ParameterValue
    Orderable part numberSMF58AH
    Standoff voltage (VR)58 V
    Leakage current at VR1 uA
    Breakdown voltage at IT64.4 V to 71.2 V
    Test current (IT)1 mA
    Clamping voltage at IPP93.6 V
    Peak pulse current2.1 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us200 W
    PackageSOD-123FL
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1066

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1066; the package line above is the
    body the part is built in.

    How to Read These Ratings

    The standoff voltage has to sit above the highest steady state level on the line, including regulation and ripple. The breakdown voltage is then one diode drop above that, and the clamp is what the downstream circuit actually sees.

    The breakdown window spans 10.56 percent, from 64.4 V to 71.2 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 58 V standing the leakage is at most 1 uA, so the part draws 0.058 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMF family this is item 87 of 130 in the Eaton catalogue.

    Series Positioning

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • The pulse current is quoted for one waveform. A different waveform changes the allowable current, and the derating curve, not the single number, is the guide.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.