| Parameter | Value |
|---|---|
| Orderable part number | SMF58CA |
| Standoff voltage (VR) | 58 V |
| Leakage current at VR | 1 uA |
| Breakdown voltage at IT | 64.4 V to 71.2 V |
| Test current (IT) | 1 mA |
| Clamping voltage at IPP | 93.6 V |
| Peak pulse current | 2.1 A |
| Polarity | Bidirectional |
| Peak pulse power, 10/1000 us | 200 W |
| Package | SOD-123FL |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +150 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data ELX1560 |
Outline drawing, pad or lead geometry and the pulse derating curves are
on the pages of Eaton Technical Data ELX1560; the package line above is the
body the part is built in.
A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.
The breakdown window spans 10.56 percent, from 64.4 V to 71.2 V. Design against the minimum, because a part at the bottom of the window starts conducting first.
At 58 V standing the leakage is at most 1 uA, so the part draws 0.058 mW on the rail. Small, but it is the number that matters on a battery input.
Within the SMF family this is item 127 of 177 in the Eaton catalogue.
Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.
Unidirectional or bidirectional?
Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.
How much capacitance does it add?
Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.
What happens if the surge exceeds the rating?
The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd