Eaton SMF6.0CA Transient Voltage Suppressor 6 V
Eaton SMF6.0CA Transient Voltage Suppressor 6 V

Eaton SMF6.0CA Transient Voltage Suppressor 6 V

Share
SMF6.0CA: transient voltage suppressor diode, 6 V standoff, 10.3 V clamp, 19.4 A pulse, 200 W, bidirectional.
    • Product Details
    • Download

    Eaton SMF6.0CA Transient Voltage Suppressor 6 V

    SMF6.0CA at a glance: transient voltage suppressor diode, 6 V standoff, 10.3 V clamp, 19.4 A pulse, 200 W, bidirectional.

    Ratings at a Glance

    ParameterValue
    Orderable part numberSMF6.0CA
    Standoff voltage (VR)6 V
    Leakage current at VR100 uA
    Breakdown voltage at IT6.67 V to 7.37 V
    Test current (IT)10 mA
    Clamping voltage at IPP10.3 V
    Peak pulse current19.4 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us200 W
    PackageSOD-123FL
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1560

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1560; the package line above is the
    body the part is built in.

    The Figures Explained

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 10.49 percent, from 6.67 V to 7.37 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 6 V standing the leakage is at most 100 uA, so the part draws 0.6 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMF family this is item 3 of 177 in the Eaton catalogue.

    What This Family Is For

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • The pulse current is quoted for one waveform. A different waveform changes the allowable current, and the derating curve, not the single number, is the guide.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.