| Parameter | Value |
|---|---|
| Orderable part number | SMF60CAH |
| Standoff voltage (VR) | 60 V |
| Leakage current at VR | 1 uA |
| Breakdown voltage at IT | 66.7 V to 73.7 V |
| Test current (IT) | 1 mA |
| Clamping voltage at IPP | 96.8 V |
| Peak pulse current | 2 A |
| Polarity | Bidirectional |
| Peak pulse power, 10/1000 us | 200 W |
| Package | SOD-123FL |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +150 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data ELX1066 |
Outline drawing, pad or lead geometry and the pulse derating curves are
on the pages of Eaton Technical Data ELX1066; the package line above is the
body the part is built in.
A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.
The breakdown window spans 10.49 percent, from 66.7 V to 73.7 V. Design against the minimum, because a part at the bottom of the window starts conducting first.
At 60 V standing the leakage is at most 1 uA, so the part draws 0.06 mW on the rail. Small, but it is the number that matters on a battery input.
Within the SMF family this is item 132 of 177 in the Eaton catalogue.
The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.
Unidirectional or bidirectional?
Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.
How do I pick the standoff voltage?
Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.
Does the peak pulse power rating apply to any surge?
No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd