Eaton SMF64A 64 V 200 W TVS Diode
Eaton SMF64A 64 V 200 W TVS Diode

Eaton SMF64A 64 V 200 W TVS Diode

Share
SMF64A: transient voltage suppressor diode, 64 V standoff, 103 V clamp, 1.9 A pulse, 200 W, unidirectional.
    • Product Details
    • Download

    Eaton SMF64A 64 V 200 W TVS Diode

    SMF64A at a glance: transient voltage suppressor diode, 64 V standoff, 103 V clamp, 1.9 A pulse, 200 W, unidirectional.

    Key Specifications

    ParameterValue
    Orderable part numberSMF64A
    Standoff voltage (VR)64 V
    Leakage current at VR1 uA
    Breakdown voltage at IT71.1 V to 78.6 V
    Test current (IT)1 mA
    Clamping voltage at IPP103 V
    Peak pulse current1.9 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us200 W
    PackageSOD-123FL
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1560

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1560; the package line above is the
    body the part is built in.

    How to Read These Ratings

    The peak pulse power rating is a 10/1000 microsecond figure: a 400 W part takes 400 W for one millisecond, not continuously. Shorter pulses allow more current, longer ones less, which is what the derating curves in the data sheet show.

    The breakdown window spans 10.55 percent, from 71.1 V to 78.6 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 64 V standing the leakage is at most 1 uA, so the part draws 0.064 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMF family this is item 92 of 130 in the Eaton catalogue.

    Where This Series Fits

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products