Eaton SMF64ALH TVS Diode, 103 V Clamp
Eaton SMF64ALH TVS Diode, 103 V Clamp

Eaton SMF64ALH TVS Diode, 103 V Clamp

Share
SMF64ALH: transient voltage suppressor diode, 64 V standoff, 103 V clamp, 3.9 A pulse, 400 W, bidirectional.
    • Product Details
    • Download

    Eaton SMF64ALH TVS Diode, 103 V Clamp

    SMF64ALH at a glance: transient voltage suppressor diode, 64 V standoff, 103 V clamp, 3.9 A pulse, 400 W, bidirectional.

    Ratings at a Glance

    ParameterValue
    Orderable part numberSMF64ALH
    Standoff voltage (VR)64 V
    Leakage current at VR1 uA
    Breakdown voltage at IT71.1 V to 78.6 V
    Test current (IT)1 mA
    Clamping voltage at IPP103 V
    Peak pulse current3.9 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us400 W
    PackageSOD-123FL
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1067

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1067; the package line above is the
    body the part is built in.

    The Figures Explained

    The peak pulse power rating is a 10/1000 microsecond figure: a 400 W part takes 400 W for one millisecond, not continuously. Shorter pulses allow more current, longer ones less, which is what the derating curves in the data sheet show.

    The breakdown window spans 10.55 percent, from 71.1 V to 78.6 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 64 V standing the leakage is at most 1 uA, so the part draws 0.064 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMF family this is item 134 of 177 in the Eaton catalogue.

    What This Family Is For

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • The pulse current is quoted for one waveform. A different waveform changes the allowable current, and the derating curve, not the single number, is the guide.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Shenzhen Gaorunxin Technology Co., Ltd