Eaton SMF64CA Transient Voltage Suppressor 64 V
Eaton SMF64CA Transient Voltage Suppressor 64 V

Eaton SMF64CA Transient Voltage Suppressor 64 V

Share
SMF64CA: transient voltage suppressor diode, 64 V standoff, 103 V clamp, 1.9 A pulse, 200 W, bidirectional.
    • Product Details
    • Download

    Eaton SMF64CA Transient Voltage Suppressor 64 V

    SMF64CA at a glance: transient voltage suppressor diode, 64 V standoff, 103 V clamp, 1.9 A pulse, 200 W, bidirectional.

    Ratings at a Glance

    ParameterValue
    Orderable part numberSMF64CA
    Standoff voltage (VR)64 V
    Leakage current at VR1 uA
    Breakdown voltage at IT71.1 V to 78.6 V
    Test current (IT)1 mA
    Clamping voltage at IPP103 V
    Peak pulse current1.9 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us200 W
    PackageSOD-123FL
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1560

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1560; the package line above is the
    body the part is built in.

    The Figures Explained

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 10.55 percent, from 71.1 V to 78.6 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 64 V standing the leakage is at most 1 uA, so the part draws 0.064 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMF family this is item 135 of 177 in the Eaton catalogue.

    Series Positioning

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • Bidirectional parts are two junctions back to back in one package. They clamp symmetrically, at the cost of roughly double the capacitance of a unidirectional part of the same die.

    Frequently Asked Questions

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.