Eaton SMF78A 78 V 200 W TVS Diode
Eaton SMF78A 78 V 200 W TVS Diode

Eaton SMF78A 78 V 200 W TVS Diode

Share
SMF78A: transient voltage suppressor diode, 78 V standoff, 126 V clamp, 1.6 A pulse, 200 W, unidirectional.
    • Product Details
    • Download

    Eaton SMF78A 78 V 200 W TVS Diode

    SMF78A at a glance: transient voltage suppressor diode, 78 V standoff, 126 V clamp, 1.6 A pulse, 200 W, unidirectional.

    Key Specifications

    ParameterValue
    Orderable part numberSMF78A
    Standoff voltage (VR)78 V
    Leakage current at VR1 uA
    Breakdown voltage at IT86.7 V to 95.8 V
    Test current (IT)1 mA
    Clamping voltage at IPP126 V
    Peak pulse current1.6 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us200 W
    PackageSOD-123FL
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1560

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1560; the package line above is the
    body the part is built in.

    Reading the Data Sheet

    These parts are avalanching junctions, so they clamp harder than a varistor and recover without the voltage drift a metal oxide part shows after a surge. The trade is capacitance and a sharper failure mode.

    The breakdown window spans 10.5 percent, from 86.7 V to 95.8 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 78 V standing the leakage is at most 1 uA, so the part draws 0.078 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMF family this is item 101 of 130 in the Eaton catalogue.

    What This Family Is For

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    Shenzhen Gaorunxin Technology Co., Ltd