SMF8.5CA: transient voltage suppressor diode, 8.5 V standoff, 14.4 V clamp, 13.9 A pulse, 200 W, bidirectional.
    • Product Details
    • Download

    Eaton SMF8.5CA TVS Diode, 14.4 V Clamp

    SMF8.5CA at a glance: transient voltage suppressor diode, 8.5 V standoff, 14.4 V clamp, 13.9 A pulse, 200 W, bidirectional.

    Specification Table

    ParameterValue
    Orderable part numberSMF8.5CA
    Standoff voltage (VR)8.5 V
    Leakage current at VR5 uA
    Breakdown voltage at IT9.44 V to 10.4 V
    Test current (IT)1 mA
    Clamping voltage at IPP14.4 V
    Peak pulse current13.9 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us200 W
    PackageSOD-123FL
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1560

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1560; the package line above is the
    body the part is built in.

    The Figures Explained

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 10.17 percent, from 9.44 V to 10.4 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 8.5 V standing the leakage is at most 5 uA, so the part draws 0.0425 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMF family this is item 13 of 177 in the Eaton catalogue.

    Positioning in the Range

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.