Eaton SMF9.0CA Transient Voltage Suppressor 9 V
Eaton SMF9.0CA Transient Voltage Suppressor 9 V

Eaton SMF9.0CA Transient Voltage Suppressor 9 V

Share
SMF9.0CA: transient voltage suppressor diode, 9 V standoff, 15.4 V clamp, 13 A pulse, 200 W, bidirectional.
    • Product Details
    • Download

    Eaton SMF9.0CA Transient Voltage Suppressor 9 V

    SMF9.0CA at a glance: transient voltage suppressor diode, 9 V standoff, 15.4 V clamp, 13 A pulse, 200 W, bidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part numberSMF9.0CA
    Standoff voltage (VR)9 V
    Leakage current at VR3 uA
    Breakdown voltage at IT10 V to 11.1 V
    Test current (IT)1 mA
    Clamping voltage at IPP15.4 V
    Peak pulse current13 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us200 W
    PackageSOD-123FL
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1560

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1560; the package line above is the
    body the part is built in.

    What the Numbers Mean

    The peak pulse power rating is a 10/1000 microsecond figure: a 400 W part takes 400 W for one millisecond, not continuously. Shorter pulses allow more current, longer ones less, which is what the derating curves in the data sheet show.

    The breakdown window spans 11 percent, from 10 V to 11.1 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 9 V standing the leakage is at most 3 uA, so the part draws 0.027 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMF family this is item 15 of 177 in the Eaton catalogue.

    Positioning in the Range

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.