Eaton SMF90CAH 90 V 200 W TVS Diode
Eaton SMF90CAH 90 V 200 W TVS Diode

Eaton SMF90CAH 90 V 200 W TVS Diode

Share
SMF90CAH: transient voltage suppressor diode, 90 V standoff, 146 V clamp, 1.4 A pulse, 200 W, bidirectional.
    • Product Details
    • Download

    Eaton SMF90CAH 90 V 200 W TVS Diode

    SMF90CAH at a glance: transient voltage suppressor diode, 90 V standoff, 146 V clamp, 1.4 A pulse, 200 W, bidirectional.

    Ratings at a Glance

    ParameterValue
    Orderable part numberSMF90CAH
    Standoff voltage (VR)90 V
    Leakage current at VR1 uA
    Breakdown voltage at IT100 V to 111 V
    Test current (IT)1 mA
    Clamping voltage at IPP146 V
    Peak pulse current1.4 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us200 W
    PackageSOD-123FL
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data ELX1066

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data ELX1066; the package line above is the
    body the part is built in.

    How to Read These Ratings

    The standoff voltage has to sit above the highest steady state level on the line, including regulation and ripple. The breakdown voltage is then one diode drop above that, and the clamp is what the downstream circuit actually sees.

    The breakdown window spans 11 percent, from 100 V to 111 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 90 V standing the leakage is at most 1 uA, so the part draws 0.09 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMF family this is item 155 of 177 in the Eaton catalogue.

    Where This Series Fits

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.