Eaton SMFE110CA Transient Voltage Suppressor 110 V
Eaton SMFE110CA Transient Voltage Suppressor 110 V

Eaton SMFE110CA Transient Voltage Suppressor 110 V

Share
SMFE110CA: transient voltage suppressor diode, 110 V standoff, 177 V clamp, 1.1 A pulse, 200 W, bidirectional.
    • Product Details
    • Download

    Eaton SMFE110CA Transient Voltage Suppressor 110 V

    SMFE110CA at a glance: transient voltage suppressor diode, 110 V standoff, 177 V clamp, 1.1 A pulse, 200 W, bidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part numberSMFE110CA
    Standoff voltage (VR)110 V
    Leakage current at VR1 uA
    Breakdown voltage at IT122 V to 135 V
    Test current (IT)1 mA
    Clamping voltage at IPP177 V
    Peak pulse current1.1 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us200 W
    PackageSOD-123FL
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11218

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11218; the package line above is the
    body the part is built in.

    Reading the Data Sheet

    These parts are avalanching junctions, so they clamp harder than a varistor and recover without the voltage drift a metal oxide part shows after a surge. The trade is capacitance and a sharper failure mode.

    The breakdown window spans 10.66 percent, from 122 V to 135 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 110 V standing the leakage is at most 1 uA, so the part draws 0.11 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMF family this is item 161 of 177 in the Eaton catalogue.

    Series Positioning

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.