| Parameter | Value |
|---|---|
| Orderable part number | SMFE120A |
| Standoff voltage (VR) | 120 V |
| Leakage current at VR | 1 uA |
| Breakdown voltage at IT | 133 V to 147 V |
| Test current (IT) | 1 mA |
| Clamping voltage at IPP | 193 V |
| Peak pulse current | 1 A |
| Polarity | Unidirectional |
| Peak pulse power, 10/1000 us | 200 W |
| Package | SOD-123FL |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +150 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data 11218 |
Outline drawing, pad or lead geometry and the pulse derating curves are
on the pages of Eaton Technical Data 11218; the package line above is the
body the part is built in.
These parts are avalanching junctions, so they clamp harder than a varistor and recover without the voltage drift a metal oxide part shows after a surge. The trade is capacitance and a sharper failure mode.
The breakdown window spans 10.53 percent, from 133 V to 147 V. Design against the minimum, because a part at the bottom of the window starts conducting first.
At 120 V standing the leakage is at most 1 uA, so the part draws 0.12 mW on the rail. Small, but it is the number that matters on a battery input.
Within the SMF family this is item 116 of 130 in the Eaton catalogue.
The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.
Why is the clamp voltage higher than the breakdown voltage?
The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.
Does the peak pulse power rating apply to any surge?
No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.
How much capacitance does it add?
Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.