SMFE12CA: transient voltage suppressor diode, 12 V standoff, 19.9 V clamp, 10.1 A pulse, 200 W, bidirectional.
    • Product Details
    • Download

    Eaton SMFE12CA Transient Voltage Suppressor 12 V

    SMFE12CA at a glance: transient voltage suppressor diode, 12 V standoff, 19.9 V clamp, 10.1 A pulse, 200 W, bidirectional.

    Specification Table

    ParameterValue
    Orderable part numberSMFE12CA
    Standoff voltage (VR)12 V
    Leakage current at VR1 uA
    Breakdown voltage at IT13.3 V to 14.7 V
    Test current (IT)1 mA
    Clamping voltage at IPP19.9 V
    Peak pulse current10.1 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us200 W
    PackageSOD-123FL
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11218

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11218; the package line above is the
    body the part is built in.

    The Figures Explained

    The peak pulse power rating is a 10/1000 microsecond figure: a 400 W part takes 400 W for one millisecond, not continuously. Shorter pulses allow more current, longer ones less, which is what the derating curves in the data sheet show.

    The breakdown window spans 10.53 percent, from 13.3 V to 14.7 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 12 V standing the leakage is at most 1 uA, so the part draws 0.012 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMF family this is item 31 of 177 in the Eaton catalogue.

    Positioning in the Range

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.