| Parameter | Value |
|---|---|
| Orderable part number | SMFE130CA |
| Standoff voltage (VR) | 130 V |
| Leakage current at VR | 1 uA |
| Breakdown voltage at IT | 144 V to 159 V |
| Test current (IT) | 1 mA |
| Clamping voltage at IPP | 209 V |
| Peak pulse current | 0.9 A |
| Polarity | Bidirectional |
| Peak pulse power, 10/1000 us | 200 W |
| Package | SOD-123FL |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +150 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data 11218 |
Outline drawing, pad or lead geometry and the pulse derating curves are
on the pages of Eaton Technical Data 11218; the package line above is the
body the part is built in.
A transient voltage suppressor is a diode biased so that it stays off at the working voltage and breaks down in a surge. The three numbers that decide whether it fits are the standoff voltage, the breakdown window and the clamping voltage at the pulse current you expect.
The breakdown window spans 10.42 percent, from 144 V to 159 V. Design against the minimum, because a part at the bottom of the window starts conducting first.
At 130 V standing the leakage is at most 1 uA, so the part draws 0.13 mW on the rail. Small, but it is the number that matters on a battery input.
Within the SMF family this is item 165 of 177 in the Eaton catalogue.
Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.
Does the peak pulse power rating apply to any surge?
No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.
How much capacitance does it add?
Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.
How do I pick the standoff voltage?
Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd