Eaton SMFE170A 170 V 200 W TVS Diode
Eaton SMFE170A 170 V 200 W TVS Diode

Eaton SMFE170A 170 V 200 W TVS Diode

Share
SMFE170A: transient voltage suppressor diode, 170 V standoff, 275 V clamp, 0.7 A pulse, 200 W, unidirectional.
    • Product Details
    • Download

    Eaton SMFE170A 170 V 200 W TVS Diode

    SMFE170A at a glance: transient voltage suppressor diode, 170 V standoff, 275 V clamp, 0.7 A pulse, 200 W, unidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part numberSMFE170A
    Standoff voltage (VR)170 V
    Leakage current at VR1 uA
    Breakdown voltage at IT189 V to 209 V
    Test current (IT)1 mA
    Clamping voltage at IPP275 V
    Peak pulse current0.7 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us200 W
    PackageSOD-123FL
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11218

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11218; the package line above is the
    body the part is built in.

    The Figures Explained

    The peak pulse power rating is a 10/1000 microsecond figure: a 400 W part takes 400 W for one millisecond, not continuously. Shorter pulses allow more current, longer ones less, which is what the derating curves in the data sheet show.

    The breakdown window spans 10.58 percent, from 189 V to 209 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 170 V standing the leakage is at most 1 uA, so the part draws 0.17 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMF family this is item 124 of 130 in the Eaton catalogue.

    Series Positioning

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • Bidirectional parts are two junctions back to back in one package. They clamp symmetrically, at the cost of roughly double the capacitance of a unidirectional part of the same die.

    Frequently Asked Questions

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products