Eaton SMFE30A 30 V 200 W TVS Diode
Eaton SMFE30A 30 V 200 W TVS Diode

Eaton SMFE30A 30 V 200 W TVS Diode

Share
SMFE30A: transient voltage suppressor diode, 30 V standoff, 48.4 V clamp, 4.1 A pulse, 200 W, unidirectional.
    • Product Details
    • Download

    Eaton SMFE30A 30 V 200 W TVS Diode

    SMFE30A at a glance: transient voltage suppressor diode, 30 V standoff, 48.4 V clamp, 4.1 A pulse, 200 W, unidirectional.

    Specification Table

    ParameterValue
    Orderable part numberSMFE30A
    Standoff voltage (VR)30 V
    Leakage current at VR1 uA
    Breakdown voltage at IT33.3 V to 36.8 V
    Test current (IT)1 mA
    Clamping voltage at IPP48.4 V
    Peak pulse current4.1 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us200 W
    PackageSOD-123FL
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11218

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11218; the package line above is the
    body the part is built in.

    What the Numbers Mean

    The standoff voltage has to sit above the highest steady state level on the line, including regulation and ripple. The breakdown voltage is then one diode drop above that, and the clamp is what the downstream circuit actually sees.

    The breakdown window spans 10.51 percent, from 33.3 V to 36.8 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 30 V standing the leakage is at most 1 uA, so the part draws 0.03 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMF family this is item 61 of 130 in the Eaton catalogue.

    Series Positioning

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    Shenzhen Gaorunxin Technology Co., Ltd