Eaton SMFE33CA TVS Diode, 53.3 V Clamp
Eaton SMFE33CA TVS Diode, 53.3 V Clamp

Eaton SMFE33CA TVS Diode, 53.3 V Clamp

Share
SMFE33CA: transient voltage suppressor diode, 33 V standoff, 53.3 V clamp, 3.8 A pulse, 200 W, bidirectional.
    • Product Details
    • Download

    Eaton SMFE33CA TVS Diode, 53.3 V Clamp

    SMFE33CA at a glance: transient voltage suppressor diode, 33 V standoff, 53.3 V clamp, 3.8 A pulse, 200 W, bidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part numberSMFE33CA
    Standoff voltage (VR)33 V
    Leakage current at VR1 uA
    Breakdown voltage at IT36.7 V to 40.6 V
    Test current (IT)1 mA
    Clamping voltage at IPP53.3 V
    Peak pulse current3.8 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us200 W
    PackageSOD-123FL
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11218

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11218; the package line above is the
    body the part is built in.

    Reading the Data Sheet

    These parts are avalanching junctions, so they clamp harder than a varistor and recover without the voltage drift a metal oxide part shows after a surge. The trade is capacitance and a sharper failure mode.

    The breakdown window spans 10.63 percent, from 36.7 V to 40.6 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 33 V standing the leakage is at most 1 uA, so the part draws 0.033 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMF family this is item 93 of 177 in the Eaton catalogue.

    Positioning in the Range

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • The pulse current is quoted for one waveform. A different waveform changes the allowable current, and the derating curve, not the single number, is the guide.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.