SMFE40A: transient voltage suppressor diode, 40 V standoff, 64.5 V clamp, 3.1 A pulse, 200 W, unidirectional.
    • Product Details
    • Download

    Eaton SMFE40A 40 V 200 W TVS Diode

    SMFE40A at a glance: transient voltage suppressor diode, 40 V standoff, 64.5 V clamp, 3.1 A pulse, 200 W, unidirectional.

    Electrical Specifications

    ParameterValue
    Orderable part numberSMFE40A
    Standoff voltage (VR)40 V
    Leakage current at VR1 uA
    Breakdown voltage at IT44.4 V to 49.1 V
    Test current (IT)1 mA
    Clamping voltage at IPP64.5 V
    Peak pulse current3.1 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us200 W
    PackageSOD-123FL
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11218

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11218; the package line above is the
    body the part is built in.

    Reading the Data Sheet

    The peak pulse power rating is a 10/1000 microsecond figure: a 400 W part takes 400 W for one millisecond, not continuously. Shorter pulses allow more current, longer ones less, which is what the derating curves in the data sheet show.

    The breakdown window spans 10.59 percent, from 44.4 V to 49.1 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 40 V standing the leakage is at most 1 uA, so the part draws 0.04 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMF family this is item 70 of 130 in the Eaton catalogue.

    Positioning in the Range

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.