| Parameter | Value |
|---|---|
| Orderable part number | SMFE40CA |
| Standoff voltage (VR) | 40 V |
| Leakage current at VR | 1 uA |
| Breakdown voltage at IT | 44.4 V to 49.1 V |
| Test current (IT) | 1 mA |
| Clamping voltage at IPP | 64.5 V |
| Peak pulse current | 3.1 A |
| Polarity | Bidirectional |
| Peak pulse power, 10/1000 us | 200 W |
| Package | SOD-123FL |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +150 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data 11218 |
Outline drawing, pad or lead geometry and the pulse derating curves are
on the pages of Eaton Technical Data 11218; the package line above is the
body the part is built in.
The standoff voltage has to sit above the highest steady state level on the line, including regulation and ripple. The breakdown voltage is then one diode drop above that, and the clamp is what the downstream circuit actually sees.
The breakdown window spans 10.59 percent, from 44.4 V to 49.1 V. Design against the minimum, because a part at the bottom of the window starts conducting first.
At 40 V standing the leakage is at most 1 uA, so the part draws 0.04 mW on the rail. Small, but it is the number that matters on a battery input.
Within the SMF family this is item 103 of 177 in the Eaton catalogue.
Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.
What happens if the surge exceeds the rating?
The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.
Why is the clamp voltage higher than the breakdown voltage?
The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.
Unidirectional or bidirectional?
Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.