| Parameter | Value |
|---|---|
| Orderable part number | SMFE5.0A |
| Standoff voltage (VR) | 5 V |
| Leakage current at VR | 100 uA |
| Breakdown voltage at IT | 6.4 V to 7 V |
| Test current (IT) | 10 mA |
| Clamping voltage at IPP | 9.2 V |
| Peak pulse current | 21.7 A |
| Polarity | Unidirectional |
| Peak pulse power, 10/1000 us | 200 W |
| Package | SOD-123FL |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +150 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data 11218 |
Outline drawing, pad or lead geometry and the pulse derating curves are
on the pages of Eaton Technical Data 11218; the package line above is the
body the part is built in.
These parts are avalanching junctions, so they clamp harder than a varistor and recover without the voltage drift a metal oxide part shows after a surge. The trade is capacitance and a sharper failure mode.
The breakdown window spans 9.375 percent, from 6.4 V to 7 V. Design against the minimum, because a part at the bottom of the window starts conducting first.
At 5 V standing the leakage is at most 100 uA, so the part draws 0.5 mW on the rail. Small, but it is the number that matters on a battery input.
Within the SMF family this is item 2 of 130 in the Eaton catalogue.
Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.
Does the peak pulse power rating apply to any surge?
No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.
How do I pick the standoff voltage?
Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.
Why is the clamp voltage higher than the breakdown voltage?
The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.