Eaton SMFE54CA Transient Voltage Suppressor 54 V
Eaton SMFE54CA Transient Voltage Suppressor 54 V

Eaton SMFE54CA Transient Voltage Suppressor 54 V

Share
SMFE54CA: transient voltage suppressor diode, 54 V standoff, 87.1 V clamp, 2.3 A pulse, 200 W, bidirectional.
    • Product Details
    • Download

    Eaton SMFE54CA Transient Voltage Suppressor 54 V

    SMFE54CA at a glance: transient voltage suppressor diode, 54 V standoff, 87.1 V clamp, 2.3 A pulse, 200 W, bidirectional.

    Ratings at a Glance

    ParameterValue
    Orderable part numberSMFE54CA
    Standoff voltage (VR)54 V
    Leakage current at VR1 uA
    Breakdown voltage at IT60 V to 66.3 V
    Test current (IT)1 mA
    Clamping voltage at IPP87.1 V
    Peak pulse current2.3 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us200 W
    PackageSOD-123FL
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11218

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11218; the package line above is the
    body the part is built in.

    What the Numbers Mean

    A transient voltage suppressor is a diode biased so that it stays off at the working voltage and breaks down in a surge. The three numbers that decide whether it fits are the standoff voltage, the breakdown window and the clamping voltage at the pulse current you expect.

    The breakdown window spans 10.5 percent, from 60 V to 66.3 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 54 V standing the leakage is at most 1 uA, so the part draws 0.054 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMF family this is item 125 of 177 in the Eaton catalogue.

    What This Family Is For

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • The standoff voltage is a DC limit. On an AC line the peak of the sine has to stay below it, which for a 120 V RMS line means a part rated well above 170 V.
    • The breakdown window is deliberately wide so that production spread does not leave parts conducting at the standoff voltage. Design to the minimum breakdown, not the typical.

    Frequently Asked Questions

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.