Eaton SMFE6.5A 6.5 V 200 W TVS Diode
Eaton SMFE6.5A 6.5 V 200 W TVS Diode

Eaton SMFE6.5A 6.5 V 200 W TVS Diode

Share
SMFE6.5A: transient voltage suppressor diode, 6.5 V standoff, 11.2 V clamp, 17.9 A pulse, 200 W, unidirectional.
    • Product Details
    • Download

    Eaton SMFE6.5A 6.5 V 200 W TVS Diode

    SMFE6.5A at a glance: transient voltage suppressor diode, 6.5 V standoff, 11.2 V clamp, 17.9 A pulse, 200 W, unidirectional.

    Key Specifications

    ParameterValue
    Orderable part numberSMFE6.5A
    Standoff voltage (VR)6.5 V
    Leakage current at VR30 uA
    Breakdown voltage at IT7.22 V to 7.98 V
    Test current (IT)10 mA
    Clamping voltage at IPP11.2 V
    Peak pulse current17.9 A
    PolarityUnidirectional
    Peak pulse power, 10/1000 us200 W
    PackageSOD-123FL
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11218

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11218; the package line above is the
    body the part is built in.

    How to Read These Ratings

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 10.53 percent, from 7.22 V to 7.98 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 6.5 V standing the leakage is at most 30 uA, so the part draws 0.195 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMF family this is item 6 of 130 in the Eaton catalogue.

    What This Family Is For

    The part goes across the line after the fuse, with the return path as short as the layout allows. Every centimetre of trace between the connector and the diode adds inductance, and the clamp the circuit sees is the diode clamp plus L di/dt.

    • The pulse current is quoted for one waveform. A different waveform changes the allowable current, and the derating curve, not the single number, is the guide.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    What happens if the surge exceeds the rating?
    The junction overheats and fails short, which then puts the full fault current through the board. That is why a fuse ahead of the suppressor is part of the protection, not an optional extra.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Shenzhen Gaorunxin Technology Co., Ltd