Eaton SMFE6.5CA Transient Voltage Suppressor 6.5 V
Eaton SMFE6.5CA Transient Voltage Suppressor 6.5 V

Eaton SMFE6.5CA Transient Voltage Suppressor 6.5 V

Share
SMFE6.5CA: transient voltage suppressor diode, 6.5 V standoff, 11.2 V clamp, 17.9 A pulse, 200 W, bidirectional.
    • Product Details
    • Download

    Eaton SMFE6.5CA Transient Voltage Suppressor 6.5 V

    SMFE6.5CA at a glance: transient voltage suppressor diode, 6.5 V standoff, 11.2 V clamp, 17.9 A pulse, 200 W, bidirectional.

    Ratings at a Glance

    ParameterValue
    Orderable part numberSMFE6.5CA
    Standoff voltage (VR)6.5 V
    Leakage current at VR30 uA
    Breakdown voltage at IT7.22 V to 7.98 V
    Test current (IT)10 mA
    Clamping voltage at IPP11.2 V
    Peak pulse current17.9 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us200 W
    PackageSOD-123FL
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11218

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11218; the package line above is the
    body the part is built in.

    The Figures Explained

    A TVS is chosen after the surge source is known. The pulse current in the table is the current the part can take, so the source impedance and the coupling network decide whether the clamp column is the number the protected circuit experiences.

    The breakdown window spans 10.53 percent, from 7.22 V to 7.98 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 6.5 V standing the leakage is at most 30 uA, so the part draws 0.195 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMF family this is item 6 of 177 in the Eaton catalogue.

    Where This Series Fits

    Keep the ground connection on the same layer as the diode. A clamp that has to travel through a via to reach the return plane loses most of its advantage at the edge speeds an ESD event produces.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • Bidirectional parts are two junctions back to back in one package. They clamp symmetrically, at the cost of roughly double the capacitance of a unidirectional part of the same die.

    Frequently Asked Questions

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    Why is the clamp voltage higher than the breakdown voltage?
    The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.

    Shenzhen Gaorunxin Technology Co., Ltd