Eaton SMFE60CA Transient Voltage Suppressor 60 V
Eaton SMFE60CA Transient Voltage Suppressor 60 V

Eaton SMFE60CA Transient Voltage Suppressor 60 V

Share
SMFE60CA: transient voltage suppressor diode, 60 V standoff, 96.8 V clamp, 2 A pulse, 200 W, bidirectional.
    • Product Details
    • Download

    Eaton SMFE60CA Transient Voltage Suppressor 60 V

    SMFE60CA at a glance: transient voltage suppressor diode, 60 V standoff, 96.8 V clamp, 2 A pulse, 200 W, bidirectional.

    Specification Table

    ParameterValue
    Orderable part numberSMFE60CA
    Standoff voltage (VR)60 V
    Leakage current at VR1 uA
    Breakdown voltage at IT66.7 V to 73.7 V
    Test current (IT)1 mA
    Clamping voltage at IPP96.8 V
    Peak pulse current2 A
    PolarityBidirectional
    Peak pulse power, 10/1000 us200 W
    PackageSOD-123FL
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationAEC-Q200
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11218

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11218; the package line above is the
    body the part is built in.

    What the Numbers Mean

    A transient voltage suppressor is a diode biased so that it stays off at the working voltage and breaks down in a surge. The three numbers that decide whether it fits are the standoff voltage, the breakdown window and the clamping voltage at the pulse current you expect.

    The breakdown window spans 10.49 percent, from 66.7 V to 73.7 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 60 V standing the leakage is at most 1 uA, so the part draws 0.06 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMF family this is item 133 of 177 in the Eaton catalogue.

    Where This Series Fits

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    How much capacitance does it add?
    Enough to matter on a fast line. A 1500 W part can be several thousand picofarads, which is fine on a supply rail and not fine on a USB or Ethernet pair.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.