| Parameter | Value |
|---|---|
| Orderable part number | SMFE7.0CA |
| Standoff voltage (VR) | 7 V |
| Leakage current at VR | 10 uA |
| Breakdown voltage at IT | 7.78 V to 8.6 V |
| Test current (IT) | 10 mA |
| Clamping voltage at IPP | 12 V |
| Peak pulse current | 16.7 A |
| Polarity | Bidirectional |
| Peak pulse power, 10/1000 us | 200 W |
| Package | SOD-123FL |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +150 °C |
| Qualification | AEC-Q200 |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data 11218 |
Outline drawing, pad or lead geometry and the pulse derating curves are
on the pages of Eaton Technical Data 11218; the package line above is the
body the part is built in.
A transient voltage suppressor is a diode biased so that it stays off at the working voltage and breaks down in a surge. The three numbers that decide whether it fits are the standoff voltage, the breakdown window and the clamping voltage at the pulse current you expect.
The breakdown window spans 10.54 percent, from 7.78 V to 8.6 V. Design against the minimum, because a part at the bottom of the window starts conducting first.
At 7 V standing the leakage is at most 10 uA, so the part draws 0.07 mW on the rail. Small, but it is the number that matters on a battery input.
Within the SMF family this is item 8 of 177 in the Eaton catalogue.
Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.
Why is the clamp voltage higher than the breakdown voltage?
The breakdown is measured at 1 mA; the clamp is measured at the full pulse current, which can be hundreds of amps. The dynamic resistance of the junction adds the difference, and that is why the two columns are never the same number.
How do I pick the standoff voltage?
Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.
Unidirectional or bidirectional?
Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd