Eaton SMTJ66CAT Transient Voltage Suppressor 66 V
Eaton SMTJ66CAT Transient Voltage Suppressor 66 V

Eaton SMTJ66CAT Transient Voltage Suppressor 66 V

Share
SMTJ66CAT: transient voltage suppressor diode, 66 V standoff, bidirectional.
    • Product Details
    • Download

    Eaton SMTJ66CAT Transient Voltage Suppressor 66 V

    SMTJ66CAT at a glance: transient voltage suppressor diode, 66 V standoff, bidirectional.

    Ratings at a Glance

    ParameterValue
    Orderable part numberSMTJ66CAT
    Standoff voltage (VR)66 V
    Leakage current at VR5 uA
    Breakdown voltage at IT72 V to 80 V
    Test current (IT)10 mA
    Clamping voltage at 3000 A120 V
    Clamping voltage at 3500 A130 V
    PolarityBidirectional
    PackageSMC (DO-214AB)
    MountingSurface mount
    Operating temperature-55 °C to +150 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11219

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11219; the package line above is the
    body the part is built in.

    Reading the Data Sheet

    A transient voltage suppressor is a diode biased so that it stays off at the working voltage and breaks down in a surge. The three numbers that decide whether it fits are the standoff voltage, the breakdown window and the clamping voltage at the pulse current you expect.

    The breakdown window spans 11.11 percent, from 72 V to 80 V. Design against the minimum, because a part at the bottom of the window starts conducting first.

    At 66 V standing the leakage is at most 5 uA, so the part draws 0.33 mW on the rail. Small, but it is the number that matters on a battery input.

    Within the SMTJ family this is item 2 of 4 in the Eaton catalogue.

    Where This Series Fits

    Place it on the protected side of any series impedance, not behind it. A TVS behind a common mode choke protects the choke, which is usually the opposite of what the design intends.

    • A unidirectional part clamps a positive surge to its forward drop and a negative one to its breakdown. On an AC or bipolar signal that asymmetry is a design error, not a detail.
    • The clamp column is measured at the rated pulse current. At a lower current the residual voltage is lower, which is why a part chosen for a small surge clamps better than its headline number suggests.

    Frequently Asked Questions

    Does the peak pulse power rating apply to any surge?
    No. It is quoted for a 10/1000 microsecond waveform. A shorter pulse allows more current and a longer one less; the derating curve converts between them.

    Unidirectional or bidirectional?
    Unidirectional on a DC rail, where the forward direction gives a low clamp for one polarity. Bidirectional on AC, on differential pairs and wherever the surge can arrive with either polarity.

    How do I pick the standoff voltage?
    Above the highest steady-state voltage the line can reach, including regulation, ripple and any temporary overvoltage the standard requires. Then check that the minimum breakdown voltage is still above that level, because production spread moves it down.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products