Eaton SR-5-1A-AP 1 A 250 Vac Time-Delay Subminiature Fuse
Eaton SR-5-1A-AP 1 A 250 Vac Time-Delay Subminiature Fuse

Eaton SR-5-1A-AP 1 A 250 Vac Time-Delay Subminiature Fuse

Share
pEaton SR-5-1A-AP — 1 A, 250 V, time-delay fuse, 35 A at rated voltage, 50 Hz interrupting./p
    • Product Details
    • Download

    Eaton SR-5-1A-AP 1 A 250 Vac Time-Delay Subminiature Fuse

    Built by Eaton, the SR-5-1A-AP carries 0.10 A, rated 250 Vac, uses a time-delay element.

    Technical Data

    ParameterRating
    ParameterValue
    Orderable part numberSR-5-1A-AP (-AP = 1,000 pcs ammo pack, 12.7 mm pitch)
    Current rating1 A
    Typical DC cold resistance0.085 Ohm
    AgencyVDE 40020842 / cURus E19180 (JDYX8, JDYX2) / CCC / PSE / SEMKO / KC
    Watts at rated current0.10 W
    Typical voltage drop100 mV at rated current
    Voltage rating250 Vac
    Typical melting I2t7.5 A2s
    CharacteristicTime-delay (T)
    BodyRadial leaded, time-delay, thru-hole, plastic cap and base, UL 94V0
    Design standardIEC 60127-3 sheet 4
    Interrupting rating35 A at rated voltage, 50 Hz

    Selection Notes

    • Interrupting capability is 35 A at rated voltage, 50 Hz — confirm the circuit's prospective fault current stays below this.
    • Time-delay element rides through motor starting and capacitive inrush without nuisance opening.
    • Startup surges of several times rated current are tolerated for a short window.
    • Working voltage must stay at or below 250 Vac; a lower-rated part is not a safe substitute.
    • Do not upsize beyond 0.10 A to stop nuisance trips — fix the cause instead.

    Typical Applications

    Engineers usually specify it for these duties:

    • EV
    • adapter
    • appliance
    • surge
    • transformer

    Q&A

    What are the ratings of the SR-5-1A-AP?

    0.10 A continuous at 250 Vac, interrupting rating 35 A at rated voltage, 50 Hz.

    Is the SR-5-1A-AP fast-acting or time-delay?

    It is time-delay. It tolerates short inrush surges.

    Can the SR-5-1A-AP be used on a higher fault-current circuit?

    No — its interrupting rating is 35 A at rated voltage, 50 Hz. Choose a part whose breaking capacity exceeds the prospective fault current.