| Parameter | Rating |
|---|---|
| Parameter | Value |
| Orderable part number | SR-5-3.15A-AP (-AP = 1,000 pcs ammo pack, 12.7 mm pitch) |
| Design standard | IEC 60127-3 sheet 4 |
| On-state drop, typical | 70.2 mV at rated current |
| Voltage rating | 250 Vac |
| Characteristic | Time-delay (T) |
| Dissipation at rating | 0.22 W |
| In (rated) | 3.15 A |
| Typical DC cold resistance | 0.018 Ohm |
| Body | Radial leaded, time-delay, thru-hole, plastic cap and base, UL 94V0 |
| Interrupting rating | 35 A at rated voltage, 50 Hz |
| Typical melting I2t | 57 A2s |
| Agency | VDE 40020842 / cURus E19180 (JDYX8, JDYX2) / CCC / PSE / SEMKO / KC |
Common installation contexts include:
Is the SR-5-3.15A-AP fast-acting or time-delay?
It is time-delay. It tolerates short inrush surges.
Can the SR-5-3.15A-AP be used on a higher fault-current circuit?
No — its interrupting rating is 35 A at rated voltage, 50 Hz. Choose a part whose breaking capacity exceeds the prospective fault current.
Shenzhen Gaorunxin Technology Co., Ltd
Shenzhen Gaorunxin Technology Co., Ltd