| Parameter | Rating |
|---|---|
| Parameter | Value |
| Orderable part number | SR-5H-800mA-AP (-AP = 1,000 pcs ammo pack, 12.7 mm pitch) |
| Interrupting rating | 100 A at rated voltage, 50 Hz |
| Voltage rating | 250/300 Vac |
| In (rated) | 800 mA |
| Typical voltage drop | 107 mV at rated current |
| Typical DC cold resistance | 0.113 Ohm |
| Physical form | Radial leaded, time-delay, thru-hole, plastic cap and base, UL 94V0 |
| Agency | cURus E19180 (JDYX2, JDYX8) / VDE / SEMKO / CCC / EK / PSE |
| Design standard | IEC 60127-3 sheet 4 |
| Typical melting I2t | 6.5 A2s |
| Characteristic | Time-delay (T) |
| Dissipation at rating | 0.09 W |
Engineers usually specify it for these duties:
Is the SR-5H-800mA-AP fast-acting or time-delay?
It is time-delay. It tolerates short inrush surges.
Can the SR-5H-800mA-AP be used on a higher fault-current circuit?
No — its interrupting rating is 100 A at rated voltage, 50 Hz. Choose a part whose breaking capacity exceeds the prospective fault current.