Eaton SR-5H-800mA-APH 800 mA 300 Vac Time-Delay Subminiature Fuse
Eaton SR-5H-800mA-APH 800 mA 300 Vac Time-Delay Subminiature Fuse

Eaton SR-5H-800mA-APH 800 mA 300 Vac Time-Delay Subminiature Fuse

Share
pEaton SR-5H-800mA-APH — 800 mA, 300 V, time-delay fuse, 100 A at 300 Vac interrupting./p
    • Product Details
    • Download

    Eaton SR-5H-800mA-APH 800 mA 300 Vac Time-Delay Subminiature Fuse

    Built by Eaton, the SR-5H-800mA-APH carries 800 mA, uses a time-delay element.

    Technical Data

    ParameterRating
    ParameterValue
    Orderable part numberSR-5H-800mA-APH (-APH = 1,000 pcs ammo pack, 12.7 mm pitch)
    Interrupting rating100 A at 300 Vac
    Packaging family-APH ammo pack / -BKH 200 in polybag / -BK2H 200 long lead
    Current rating800 mA
    CharacteristicTime-delay (T), high inrush withstand
    Typical voltage drop107 mV at rated current
    BodyRadial leaded thru-hole, plastic cap and base, UL 94V0
    Typical DC cold resistance0.113 Ohm
    Design standardIEC 60127-3 sheet 4
    AgencycURus E19180 (JDYX2, JDYX8) - the sub-1 A ratings carry only the UR mark
    Un (rated)300 Vac
    Dissipation at rating0.09 W
    Typical melting I2t6.5 A2s

    Selection Notes

    • Interrupting capability is 100 A at 300 Vac — confirm the circuit's prospective fault current stays below this.
    • Time-delay element rides through motor starting and capacitive inrush without nuisance opening.
    • Startup surges of several times rated current are tolerated for a short window.
    • Do not upsize beyond 800 mA to stop nuisance trips — fix the cause instead.

    Typical Applications

    Engineers usually specify it for these duties:

    • transformer

    Part Number and Packing

    Order code SR-5H-800mA-APH from Eaton, supplied in -APH ammo pack / -BKH 200 in polybag / -BK2H 200 long lead. Confirm the exact suffix before release.

    Q&A

    Is the SR-5H-800mA-APH fast-acting or time-delay?

    It is time-delay. It tolerates short inrush surges.

    Can the SR-5H-800mA-APH be used on a higher fault-current circuit?

    No — its interrupting rating is 100 A at 300 Vac. Choose a part whose breaking capacity exceeds the prospective fault current.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products