Eaton STN102050UL80 ESD Suppressor 5 V
Eaton STN102050UL80 ESD Suppressor 5 V

Eaton STN102050UL80 ESD Suppressor 5 V

Share
STN102050UL80: ESD protection suppressor, 5 V rated.
    • Product Details
    • Download

    Eaton STN102050UL80 ESD Suppressor 5 V

    STN102050UL80 at a glance: ESD protection suppressor, 5 V rated.

    Specification Table

    ParameterValue
    Orderable part numberSTN102050UL80
    Reverse working voltage5 V
    Breakdown voltage (min / typ / max)6 V
    Leakage current at VR1 uA
    Peak pulse current5 A
    Clamping voltage at 1 A12 V
    Junction capacitance, max0.8 pF
    Package0402 / DFN
    MountingSurface mount
    Operating temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11132

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11132; the package line above is the
    body the part is built in.

    How to Read These Ratings

    The trigger voltage is measured with a transmission line pulse, not with a multimeter. It is the point where the structure snaps on, and it sits well above the standoff voltage so that normal signal swing does not trip it.

    Within the STN10 family this is item 2 of 2 in the Eaton catalogue.

    Series Positioning

    The ground pin goes to the connector ground, not to a distant plane. The discharge returns through that connection, and a long path turns the clamp into a radiator.

    • A suppressor does not replace galvanic isolation. It limits the transient, but a sustained fault still puts the full line voltage across the board.
    • The trigger voltage is a snapback figure. Between the standoff voltage and the trigger the part is still off, so a slow surge that stays in that window is passed through rather than clamped.

    Frequently Asked Questions

    Will it survive repeated strikes?
    The datasheet quotes a pulse count at the qualification level, typically over a thousand at 8 kV contact. That is the number to compare against the events the port is expected to see.

    Does the package matter?
    It sets the capacitance and the thermal mass. The same die in a 0201 and a 0603 gives different surge capability, so the package is part of the electrical choice, not just the footprint.

    What does bidirectional mean in practice?
    The part clamps either polarity with the same characteristic, so it can be placed either way round and protects a line that swings below ground.