Eaton STN161090U602 ESD Suppressor 9 V
Eaton STN161090U602 ESD Suppressor 9 V

Eaton STN161090U602 ESD Suppressor 9 V

Share
STN161090U602: ESD protection suppressor, 9 V rated, 600 pF.
    • Product Details
    • Download

    Eaton STN161090U602 ESD Suppressor 9 V

    STN161090U602 at a glance: ESD protection suppressor, 9 V rated, 600 pF.

    Electrical Specifications

    ParameterValue
    Orderable part numberSTN161090U602
    Reverse working voltage9 V
    Breakdown voltage (min / typ / max)9.5 V / 10.5 V / 12.5 V
    Leakage current at VR1 uA
    Peak pulse current90 A
    Clamping voltage17 V
    Junction capacitance, typ600 pF
    Junction capacitance, max750 pF
    PackageDFN 1.6 x 1.0
    MountingSurface mount
    Operating temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11134

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11134; the package line above is the
    body the part is built in.

    The Figures Explained

    An ESD suppressor is a small clamp that sits on a connector pin and does nothing until a discharge arrives. Because the discharge is nanoseconds long, the part is chosen on capacitance and trigger voltage rather than on energy.

    The 600 pF typical capacitance sets the highest data rate the part can sit on without distorting the eye.

    Within the STN161 family this is item 4 of 6 in the Eaton catalogue.

    Series Positioning

    The ground pin goes to the connector ground, not to a distant plane. The discharge returns through that connection, and a long path turns the clamp into a radiator.

    • A suppressor does not replace galvanic isolation. It limits the transient, but a sustained fault still puts the full line voltage across the board.
    • The trigger voltage is a snapback figure. Between the standoff voltage and the trigger the part is still off, so a slow surge that stays in that window is passed through rather than clamped.

    Frequently Asked Questions

    What does bidirectional mean in practice?
    The part clamps either polarity with the same characteristic, so it can be placed either way round and protects a line that swings below ground.

    Does the package matter?
    It sets the capacitance and the thermal mass. The same die in a 0201 and a 0603 gives different surge capability, so the package is part of the electrical choice, not just the footprint.

    Will it survive repeated strikes?
    The datasheet quotes a pulse count at the qualification level, typically over a thousand at 8 kV contact. That is the number to compare against the events the port is expected to see.