Eaton STN202150U952 950 pF ESD Protection Diode
Eaton STN202150U952 950 pF ESD Protection Diode

Eaton STN202150U952 950 pF ESD Protection Diode

Share
STN202150U952: ESD protection suppressor, 15 V rated, 950 pF.
    • Product Details
    • Download

    Eaton STN202150U952 950 pF ESD Protection Diode

    STN202150U952 at a glance: ESD protection suppressor, 15 V rated, 950 pF.

    Key Specifications

    ParameterValue
    Orderable part numberSTN202150U952
    Reverse working voltage15 V
    Breakdown voltage (min / typ / max)16 V / 17.5 V / 19 V
    Leakage current at VR1 uA
    Clamping voltage at 50 A25 V
    Junction capacitance, typ950 pF
    Junction capacitance, max1200 pF
    PackageDFN 2 x 2
    MountingSurface mount
    Operating temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11135

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11135; the package line above is the
    body the part is built in.

    How to Read These Ratings

    An ESD rating is a qualification, not a life count: IEC 61000-4-2 level 4 is 8 kV contact and 15 kV air, and the part is expected to survive that repeatedly because the energy per event is small.

    The 950 pF typical capacitance sets the highest data rate the part can sit on without distorting the eye.

    Within the STN202 family this is item 4 of 5 in the Eaton catalogue.

    Series Positioning

    The ground pin goes to the connector ground, not to a distant plane. The discharge returns through that connection, and a long path turns the clamp into a radiator.

    • A suppressor does not replace galvanic isolation. It limits the transient, but a sustained fault still puts the full line voltage across the board.
    • The trigger voltage is a snapback figure. Between the standoff voltage and the trigger the part is still off, so a slow surge that stays in that window is passed through rather than clamped.

    Frequently Asked Questions

    What does bidirectional mean in practice?
    The part clamps either polarity with the same characteristic, so it can be placed either way round and protects a line that swings below ground.

    Does the package matter?
    It sets the capacitance and the thermal mass. The same die in a 0201 and a 0603 gives different surge capability, so the package is part of the electrical choice, not just the footprint.

    Will it survive repeated strikes?
    The datasheet quotes a pulse count at the qualification level, typically over a thousand at 8 kV contact. That is the number to compare against the events the port is expected to see.

    Shenzhen Gaorunxin Technology Co., Ltd

    Online message

    Shenzhen Gaorunxin Technology Co., Ltd

    Related Products