| Parameter | Value |
|---|---|
| Orderable part number | STN202XXXUXXX |
| Package | DFN 2 x 2 |
| Mounting | Surface mount |
| Operating temperature | -55 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data 11135 |
Outline drawing, pad or lead geometry and the pulse derating curves are
on the pages of Eaton Technical Data 11135; the package line above is the
body the part is built in.
The trigger voltage is measured with a transmission line pulse, not with a multimeter. It is the point where the structure snaps on, and it sits well above the standoff voltage so that normal signal swing does not trip it.
Within the STN202 family this is item 1 of 5 in the Eaton catalogue.
Place the suppressor directly at the connector, before any series component. Its job is to take the discharge before it enters the board, and a few millimetres of trace is enough to let the pulse past it.
Will it survive repeated strikes?
The datasheet quotes a pulse count at the qualification level, typically over a thousand at 8 kV contact. That is the number to compare against the events the port is expected to see.
Can it be used on a power rail?
Yes, within the rated voltage, but the energy per event on a power rail is much higher than an ESD strike. For supply transients a TVS with a joule rating is the right part, not an ESD suppressor.
What does bidirectional mean in practice?
The part clamps either polarity with the same characteristic, so it can be placed either way round and protects a line that swings below ground.