Eaton STN202XXXUXXX TVS ESD Suppressor DFN 2 x 2
Eaton STN202XXXUXXX TVS ESD Suppressor DFN 2 x 2

Eaton STN202XXXUXXX TVS ESD Suppressor DFN 2 x 2

Share
STN202XXXUXXX: ESD protection suppressor.
    • Product Details
    • Download

    Eaton STN202XXXUXXX TVS ESD Suppressor DFN 2 x 2

    STN202XXXUXXX at a glance: ESD protection suppressor.

    Specification Table

    ParameterValue
    Orderable part numberSTN202XXXUXXX
    PackageDFN 2 x 2
    MountingSurface mount
    Operating temperature-55 °C to +125 °C
    QualificationCommercial grade
    RoHSCompliant, halogen free
    Data sheetEaton Technical Data 11135

    Outline drawing, pad or lead geometry and the pulse derating curves are
    on the pages of Eaton Technical Data 11135; the package line above is the
    body the part is built in.

    Reading the Data Sheet

    The trigger voltage is measured with a transmission line pulse, not with a multimeter. It is the point where the structure snaps on, and it sits well above the standoff voltage so that normal signal swing does not trip it.

    Within the STN202 family this is item 1 of 5 in the Eaton catalogue.

    Positioning in the Range

    Place the suppressor directly at the connector, before any series component. Its job is to take the discharge before it enters the board, and a few millimetres of trace is enough to let the pulse past it.

    • Capacitance is not a small effect on a data line. Read the capacitance at the frequency the line actually carries, not the 1 MHz test figure alone.
    • The trigger voltage is a snapback figure. Between the standoff voltage and the trigger the part is still off, so a slow surge that stays in that window is passed through rather than clamped.

    Frequently Asked Questions

    Will it survive repeated strikes?
    The datasheet quotes a pulse count at the qualification level, typically over a thousand at 8 kV contact. That is the number to compare against the events the port is expected to see.

    Can it be used on a power rail?
    Yes, within the rated voltage, but the energy per event on a power rail is much higher than an ESD strike. For supply transients a TVS with a joule rating is the right part, not an ESD suppressor.

    What does bidirectional mean in practice?
    The part clamps either polarity with the same characteristic, so it can be placed either way round and protects a line that swings below ground.