| Parameter | Value |
|---|---|
| Orderable part number | STS232033U202 |
| Standoff voltage (VRWM) | 3.3 V |
| Breakdown voltage (min / typ / max) | 4 V |
| Leakage current at VRWM | 5 uA max |
| Peak pulse power, 8/20 us, per line | 350 W |
| Clamping voltage at 1 A | 8 V |
| Clamping voltage at 25 A | 14 V |
| Junction capacitance at 1 MHz, per line | 200 pF typ / 240 pF max |
| Channels | 2 |
| Polarity | Unidirectional |
| ESD capability, IEC 61000-4-2 | +/-8 kV contact / +/-15 kV air |
| Package | SOT-23 (S23) |
| Mounting | Surface mount |
| Moisture sensitivity level | MSL 3 |
| Operating junction temperature | -55 °C to +125 °C |
| Qualification | Commercial grade |
| RoHS | Compliant, halogen free |
| Data sheet | Eaton Technical Data 11154 |
The outline drawing, pad geometry, derating curves and the pulse
waveform are on the pages of Eaton Technical Data 11154. Values above are
read directly from the electrical table for this part number, not from the family
summary.
A diode array is not a fuse and not a filter. It conducts for the duration of the transient, folds the pulse down to its clamping voltage, and returns to a leakage current measured in microamps. The energy it absorbs is the pulse current times the clamp, for as long as the pulse lasts.
At 25 A the clamp sits at 14 V, or 4.24 times the 3.3 V standoff. The protected pin sees that figure for the duration of the pulse, so it is the one to compare with the absolute maximum in the transceiver data sheet. The 8/20 microsecond peak pulse power rating for this part is 350 W per line; the derating curve in the data sheet shortens the allowable current as the pulse gets longer.
200 pF per line is 0.8 ohms of reactance at 1 GHz and 8.0 ohms at 100 MHz. A real load on a fast line: this grade fits a slow bus or a DC rail, not a high speed data pair.
Standing at 3.3 V the part draws at most 5 uA, which is 16.5 uW of dissipation on the line. That is the figure that matters on a battery rail that never powers down.
All 2 lines return through the common ground pin. That is the point of the array: one connection to the connector ground instead of one per line, and clamps that stay within millivolts of each other during the event.
A diode array is not a fuse and not a filter. It conducts for the duration of the transient, folds the pulse down to its clamping voltage, and returns to a leakage current measured in microamps. The energy it absorbs is the pulse current times the clamp, for as long as the pulse lasts.
On a multi-line bus, put one array at the connector rather than one part per line spread along the board. The lines then share a single ground inductance, and the clamps stay within a few millivolts of each other during the event.
How is the working voltage chosen?
Above the highest steady state voltage the line can reach, including the fault levels the standard for that interface allows. Then confirm the minimum breakdown voltage is still above that level, because production spread moves it down.
What happens if the surge exceeds the rating?
The junction overheats and fails short, which then applies the fault current to the board. A fuse or a series resistor ahead of the array is part of the protection scheme, not an accessory.
How many of these parts survive repeated strikes?
The IEC 61000-4-2 rating is a qualification level, not a life count. The part is expected to take the strike repeatedly at the rated level because the energy per event is small, but a higher level shortens that life.
Shenzhen Gaorunxin Technology Co., Ltd